Lukas PC 650 User Manual

Page 22

Advertising
background image

22

After completing the work and before stopping the unit, place all connected units to the base
setting (storage setting). You can then stop, or switch off, the motor on the unit, and if you
are using an electric motor this should be disconnected from the mains.

9. Dismantling the equipment / deactivation following operation

CAUTION!
Several people may be required to transport to the storage location, depending
on the weight of the hydraulic power unit.

If the connected hose lines are to be dismantled during shut-down, decouple as described
in Chapter "Connecting the hose lines". Then replace the dust protection caps onto the plug
couplings.
Clean any coarse contamination from the hydraulic tank before putting into storage. If the
storage period is extended then the unit must be cleaned completely externally and the
mechanically moving parts must be oiled.
If storing a unit with combustion engine, you should also remove the fuel from the fuel tank
and disconnect and/or remove the starter battery.
Avoid storing the hydraulic power units in a damp environment.
Observe the additional regulations in the separate operating instructions for the hoses.

WARNING for power units with combustion engines!
Check that the engine switch is set to the “OFF“ position and remains there to
prevent the unwanted starting of the power unit!

ATTENTION!
The operating pressure in the system must be dissipated before uncoupling
the hoses.
When the rerailing work is complete you must release the operating pressure
in the installation/system.

Couplings:

Advertising
This manual is related to the following products: