Lukas PC 650 User Manual

Page 37

Advertising
background image

37

Fault

Check

Cause

Solution

Connected
equipment does
not reach its end
position

Check hydraulic
fl uid volume in
hydraulic tank

Insuffi cient fl uid in the
hydraulic tank

Top up hydraulic fl uid
to the maximum fi ll
level

Attention! Before
topping up, return the
connected equipment
to the base position!

Usable hydraulic fl uid
volume of the unit is
insuffi cient

Use a different unit
with a demand quantity
below the maximum
usable quantity of the
power unit

Connected
equipment does
not reach its
performance data
(force)

Maximum permitted
operating pressure
of the pump is not
reached

Have the pressure
limiting valve reset or
repaired by authorised
dealer or directly by
LUKAS

Pump block defective

Have it repaired by
authorised dealer or
directly by LUKAS

Connected unit
defective

Rectifi cation see
operating instructions
of the connected unit

During function test:
A pressure gauge
installed between
the equipment
and the hydraulic
power unit does
not indicate the
maximum operating
pressure of the
power unit.

Check the
stated data of
the connected
equipment

The operating
pressure of the
connected equipment
is locked internally

No repair or fault
rectifi cation required

Connected unit
defective

Consult the separate
operating manual
for the connected
equipment

Hydraulic unit
defective

Have it repaired by
authorised dealer or
directly by LUKAS

Advertising
This manual is related to the following products: