2 hydraulic units with combustion engine – Lukas PC 650 User Manual

Page 24

Advertising
background image

24

Visual Inspection

Hydraulic power units
• check that all hydraulic connections are still tight
• general tightness, no leaks (sweated oils do not have any infl uence on the function),
• is there any detectable damage to the engine, connecting blocks, on the frame or the side

sections,

• Is there any sign of damage to the hydraulics and/or fuel tank,
• Side plates present and tightened,
• Presence and legibility of the identifi cation plate, all actuation signs, instruction signs,

markings and warnings,

• The presence and perfect condition of all covers (e.g. exhaust defl ector),
• The presence and perfect condition of thermal protection mats,
• Is there still a minimum distance of 10 mm between the tanks and the hot parts of the

engine,

• All

fl uid levels are within the specifi ed tolerances,

• Are the starters in proper working order and undamaged?
• Are the electrical cables in proper working order and undamaged?
• Is the electric starter battery in proper working order and undamaged?
• Couplings must be easy to couple,
• Dust protection caps must be available,
• All required accessory parts (e.g. sparking plug, sparking plug spanner and fuel can) are

present.

• Are the extending handles undamaged and functional

10.2 Hydraulic units with combustion engine

Functional test

• No unusual noises
• Starter

functioning?

• Engine switch fully functional,
• Tests for maximum load (connect to control table and apply pressure with the valve

switching lever (a unit must not be connected to the control table) until the maximum
operating pressure is reached. Read-off via pressure gauge on control table).

Advertising