OPERATION SAFETY

Electrical Hazards

• This machine is not insulated and does not provide protection from contact or

proximity to electrical current.

• Maintain safe distance from electrical lines, apparatus or any energized (exposed

or insulated) parts according to the Minimum Safe Approach Distance (MSAD).

• Allow for machine movement and electrical line swaying.

Voltage Range

(Phase to Phase)

MINIMUM SAFE APPROACH

DISTANCE (MSAD)

0 to 300 V

AVOID CONTACT

Over 300 V to 50 KV

3 m (10 ft)

Over 50 KV to 200 KV

5 m (15 ft)

Over 200 KV to 350 KV

6 m (20 ft)

Over 350 KV to 500 KV

8 m (25 ft)

Over 500 KV to 750 KV

11 m (35 ft)

Over 750 KV to 1000 KV

14 m (45 ft)

Note: This requirement shall apply except where employer, local or
governmental regulations are more stringent.