SECTION 1 - SPECIFICATIONS

3121111

– JLG Lift –

1-3

4 Extends from
front of machine

1

2

3

Note:

500 Hrs. = 3 months
1000 Hrs. = 6 months
2000 Hrs. = 1 year
4000 Hrs. = 2 years

Table 1-4. Lubrication Chart

INDEX

NO

COMPONENT

NUMBER/TYPE LUBE POINTS

LUBE METHOD

INTERVAL

HOURS

1

Hydraulic Oil Reservoir

Fill Cap/Drain Plug

HO - Check HO Level

HO - Change HO

10/500

2

Hydraulic Filter Element

N/A

Initial Change - 50 Hours

250

3

Rail Slides

N/A

MPG - Brush

100

4

Engine Crankcase

Fill Cap/Drain Plug

Check Engine Oil Level

10/100

KEY TO LUBRICANTS:

MPG - Multi-purpose Grease

EPGL - Extreme Pressure Gear Lube

HO - Hydraulic Oil (Mobil 424)

TO AVOID PERSONAL INJURY, USE SAFETY PROP FOR ALL
MAINTENANCE REQUIRING PLATFORM TO BE ELEVATED.

NOTE: Be sure to lubricate like items on each side

NOTE: Recommended lubricating intervals are based on

machine operations under normal conditions. For
machines used in multi-shift operations and/or
exposed to hostile environments or conditions, lubri-
cation frequencies must be increased accordingly.

Operate hydraulic functions through one complete
cycle before checking hydraulic oil level in tank. Oil
should be visible in ADD sight window on hydraulic
tank. If oil is not visible, add oil until oil is visible in
both ADD and FULL sight windows on tank. Do not
overfill tank.

Any time the pump coupling is removed, coat
splines of coupling with Texaco Code 1912 grease
prior to assembly.

Figure 1-1. Lubrication Diagram

Advertising
This manual is related to the following products: