Machine model adjustment -25 – JLG 400CRT ANSI Service Manual User Manual

Page 39

Advertising
background image

SECTION 2 - PROCEDURES

3121111

– JLG Lift –

2-25

Table 2-4. Machine Model Adjustment

Adjustment

Adjustment range

Default Values - Gas

Default Values - Diesel

DRIVE

Accel

1.0 to 5.0 sec

4

4

Decel

1.0 to 5.0 sec

2

2

FWD MIN

0 to 100%

21

21

FWD MAX

0 to 100%

48

48

FWD ELEV

0 to 35%

30

30

REV MIN

0 to 100%

21

21

REV MAX

0 to 100%

52

52

REV ELEV

0 to 35%

30

30

LO MAX

35 to 65%

50

50

ENGINE SPD

2800 to 3800 RPM

3600

3000

GAIN

0 to 999

180

50

DROOP

0 to 999

200

250

STABILITY

0 to 999

170

125

LIFT

Accel

0.2 TO 5.0

4

4

Decel

0.2 TO 5.0

0.5

0.5

UP MIN ENG

1400 TO 2200 RPM

2000

2000

UP MAX ENG

2600 to 3600 RPM

3000

3000

LO MAX

35 to 55%

50

50

GAIN

0 to 999

150

10

DROOP

0 to 999

220

240

STABILITY

0 to 999

125

70

IDLE

ENGINE SPEED

1200 TO 1500 rpm

1500

1500

GAIN

0 to 999

150

10

DROOP

0 to 999

250

85

STABILITY

0 to 999

100

90

MIN ACT

0 T0 100%

19

25

MAX ACT L/D

0 T0 100%

60

100

MAX ACT IDLE

0 T0 100%

55

40

CUT ACT

200 TO 2800 RPM

500

500

Advertising
This manual is related to the following products: