7 main power circuit troubleshooting, Unit will not power up from ground control, Overview of procedure – JLG 20VP (3120728) Service Manual User Manual

Page 77: Check for these obvious conditions first, Battery voltage 24 volts. (fully charge batteries), Battery connections clean and tight, Key switch positioned to ground (grnd) control, Emergency stop switch pulled out. (reset position), Main power circuit troubleshooting -17, Unit will not power up from ground control -17

Advertising
background image

SECTION 3 - TROUBLESHOOTING

3120728

– JLG Lift –

3-17

3.7

MAIN POWER CIRCUIT TROUBLESHOOTING

Unit Will Not Power Up From Ground Control

Overview Of Procedure

The following procedure tests the circuits from the Battery (+) terminal through the Ground Control Box and to the Main
Contactor Relay and Main Contactor for 24 volts or more. Also the Lift Up/Down Relay circuit is tested.

Check For These Obvious Conditions First:

• Battery voltage 24 volts. (Fully charge batteries)

• Battery connections clean and tight.

• Key switch positioned to Ground (GRND) control.

• Emergency stop switch pulled out. (Reset Position)

Table 3-4. Unit will not Power Up From Ground Control.

STEP

ACTION

SPEC

YES

NO

1.

Check the 5 amp inline fuse on the Red 1-1 wire from the battery (+)
terminal to the ground control box, key switch.
(Under pump/motor cover).

24 volts

OK, go to Step 2

Replace Fuse

Ground Control Box Assembly (Disassembled)

2.

Is there 24 volts or more reading at the key switch, terminal B.

24 volts

Go to Step 3

Check Wiring

from Battery to

Terminal B.

Repair or Replace

3.

Check for 24 volts or more on the Yel/Red, 2-7 wire from the key
switch to the E-stop switch.

24 volts

Go to Step 4

Repair wiring or

Replace Key

Switch

4.

Check for 24 volts or more on the Yel/Red, 2-8 wire from the E-stop
to the Ground Control Relay, terminal 86.

Go to Step 5

Repair wiring or
Replace E-Stop

Switch

5.

Check for 24 volts or more on the Yel/Red, 2-4 wire from the E-stop
to the Main Contactor Relay, terminal 87.

Go to Step 6

Repair wiring or
Replace E-Stop

Switch

Main Contactor Circuit

6.

Check for 24 volts or more on the Yel/Red, 2-4 wire from the Main
Contactor Relay, terminal 87 to the Main Contactor.

Go to Step 7

Repair wiring or

Replace Main

Contactor Relay

7.

Did Main Contactor close?

Go to Step 9

Go to Step 8

8.

Is the Black ground wire connection from the Main Contactor to
ground OK?

Replace Main

Contactor

Repair Ground

Wiring

9.

At this point, 24 volts should be present at the following terminal
points;

• Terminal 86 on the Ground Control Relay.
• Main Contactor, Yel/Red, 2-4 wire.

10.

With Main Contactor engaged, 24 volts or more should be present at
the following terminal points;

• Pump Motor - 21’ cable #1.
• Yel/Red, 2-6 wire on the Pump Contactor.
• Yel/Red, 2-6 wires on the Lift Up/Down Relay.