No power at platform control, Overview of procedure, Check for these obvious conditions first – JLG 20VP (3120728) Service Manual User Manual

Page 78: Battery voltage 24 volts. (fully charge batteries), Keyswitch is turned to plat. (platform), Table 3-5. no power at platform control, No power at platform control -18

Advertising
background image

SECTION 3 - TROUBLESHOOTING

3-18

– JLG Lift –

3120728

No Power At Platform Control

Overview Of Procedure

The following procedure checks voltage and ground starting from the power source (batteries) through the ground control
station (key switch/E-stop) to the MC-1 box and finally to the platform control.

Check For These Obvious Conditions First:

• Battery voltage 24 volts. (Fully charge batteries)

• Keyswitch is turned to PLAT. (Platform)

• Both Emergency Stop Switches Reset (Ground/Platform). (Out)

• Connection of X102 Cable from MC-1 box to Platform Control, secure on both ends.

Table 3-5. No Power At Platform Control.

STEP

ACTION

SPEC

YES

NO

1.

Check if the inline 5 amp fuse is blown on the Red, 1-1 wire at the
ground control station. (Ground control cover must be removed)

If OK, go to Step 2

Replace Fuse

2.

Check voltage to the Yel/Red, 2-2 wire at the MC-1 box, X101 con-
nector, pin 3.

24 volts

Go to Step 3

Perform the E-

Stop/Key Switch

Circuit Check

(Table 3-17)

3.

Check for Ground to the Black wire at the MC-1 box, X101 connec-
tor, pin A2.

Ground

Go to Step 4

Check connec-

tion/wiring

between Battery

and X101, Pin A2

4.

Check voltage to the Yel/Red, 2-3 wire at the MC-1 box, X101 con-
nector, pin 5.

24 volts

Go to Step 5

Replace MC-1

Control Box

5.

Check voltage to the Yel/Red, 2-5 wire at the MC-1 box, X101 con-
nector, pin A1.

24 volts

Go to Step 13

Go to Step 6

6.

Check voltage to the Yel/Red, 2-2 wire at the MC-1 box, X101 con-
nector, pin 3, from the Power Relay pin 30.

24 volts

Go to Step7

Check the wire

between the

Power Relay and

Connection

7.

Check voltage to the Power Relay, pin 87.

24 volts

Go to Step 9

Go to Step 8

8.

Check for Ground to the Power Relay on the Black wire pin 85, to
Ground.

Ground

Replace Relay

Check wiring to

Ground

Connection

9.

Check voltage to the Yel/Red, 2-4 wire at the Main Contactor from
the Power Relay, pin 87.

24 volts

Go to Step 10

Check the Yel/

Red, 2-4 Wiring

10.

Check for Ground, on the Black wire to the Main Contactor.

Ground

Go to Step 11

Check wiring to

Ground

Connection

11.

Check voltage at the Battery Cable from Battery to Main Contactor.

24 volts

Go to Step 12

Check Battery

Cable

12.

Check voltage to the Yel/Red, 2-5 wire at the Main Contactor.

24 volts

Check Yel/Red 2-

5 Wire

Replace Main

Contactor