9 mast troubleshooting, Platform will not lift up using platform control, Overview of procedure – JLG 20VP (3120728) Service Manual User Manual

Page 90: Check for these obvious conditions first, Battery voltage 24 volts. (fully charge batteries), Platform loaded within maximum allowable capacity, Mast troubleshooting -30

Advertising
background image

SECTION 3 - TROUBLESHOOTING

3-30

– JLG Lift –

3120728

3.9

MAST TROUBLESHOOTING

Platform Will Not Lift Up Using Platform Control

Overview Of Procedure

This procedure examines the complete pump motor, ground control and pump valves electrical circuits.

Check For These Obvious Conditions First:

• Battery voltage 24 volts. (Fully charge batteries)

• Platform loaded within maximum allowable capacity.

• Hydraulic oil is within it’s specified operating temperature range.

Table 3-20. Platform Will Not Lift Up Using Platform Control.

STEP

ACTION

SPEC

YES

NO

1.

Will platform lift from ground control switch?
Note: Key switch must be set to GRND to test this.

Go to Step 2

See (Figure 3-24)

2.

Does pump motor run?

Go to Step 3

See Pump Circuit

Check

(Table 3-21 )

3.

Are the down and dump valves opening/closing properly?
Note: If machine will not lift and hydraulic oil is visible flowing in the
hydraulic tank, the dump valve is stuck in the open position.

Go to Step 4

See Pump Valves

Circuit Check

(Table 3-22 )

4.

Is the pressure set properly on the pump?

Go to Step 5

Set to correct

pressure specifi-

cation per this

Service Manual

5.

Is the lift cylinder OK?

Go to Step 6

Rebuild or

Replace Lift Cyl.

6.

Are the mast sections operating freely?

Consult

Factory

Check Mast,

Rebuild

if Necessary