14.

Check the Black to ground on the pump contactor.

Ground

Go to Step 15

Tighten/Repair

Connection

POWER RELAY CIRCUIT

15.

Check the Yel/Red, 2-4 wire, #87 on the Power Relay to the main
contactor, and to diode at E-Stop for 24 volts.
Note: Power will stop at diode, silver line should be away from the E-
Stop.

24 volts

Go to Step 16

Tighten/Repair

Connection

16.

Check the Yel/Red, 2-2 wire, #30 on the Power Relay to the E-stop
and to the MC-1 box, X101 connector pin 3, for 24 volts.

24 volts

Go to Step 17

Tighten/Repair

Connection

17.

Check the Black, #85 pin on the Power Relay for connection to
ground at pump contactor.

Ground

Go to Step

Tighten/Repair

Connection

18.

Check the Yel/Red, 2-3 wire, #86 on the Power Relay to the MC-1
box, X101 connector pin 5, for 24 volts when the platform control is
powered up.

Go to Step

Tighten/Repair

Connection

Table 3-22. Pump Valves Circuit

• Battery voltage 24 volts. (Fully charge batteries)
• Set key switch to Platform and set the Emergency Stop Button to the RESET position.
• Down Valve should be normal (closed).
• Dump Valve (up) should be normal (open).
• If machine will not lift and hydraulic oil is visible flowing in the hydraulic tank, the dump valve is stuck open.

STEP

ACTION

SPEC

YES

NO

LIFT UP - (CONDITIONS WHEN PUMP MOTOR IS RUNNING)

1.

Pump Contactor Coil:

Yel/Red, 2-6 wire - 24 volts
Tan, 55-1 wire - Ground

2.

Lift Up Valve Coil: Yel/Red, 2-6 wire - 24 volts

Tan, 3-1 wire - Ground

LIFT UP - (CHECK WHEN PUMP MOTOR IS NOT RUNNING)

3.

Pump Contactor Coil:

Yel/Red, 2-6 wire - 24 volts
Tan, 55-1 wire - 24 volts

4.

Lift Up Valve Coil: Yel/Red, 2-6 wire - 24 volts

Tan, 3-1 wire - 24 volts

LIFT DOWN - (CHECK WHEN DOWN AND ENABLE PADS ARE PUSHED ON THE PLATFORM CONTROL)

5.

Lift Down Valve Coil:Yel/Red, 2-6 wire - 24 volts

Tan, 4-1 wire - Ground

LIFT DOWN - (CHECK WHEN NO FUNCTION ARE ENABLED ON THE PLATFORM CONTROL)

6.

Lift Down Valve Coil:Yel/Red, 2-6 wire - 24 volts

Tan, 4-1 wire - 24 volts

Table 3-21. Pump Circuit