-9-

Electrical Wiring Work

WARNING

• All electrical work must be performed by an authorized electrician,

in compliance with local electrical equipment standards and internal

wiring codes. Never allow an unauthorized person to perform electrical

work because it is not only against the law, but it can also be extremely

dangerous.

• Improper wiring can lead to current leakage, electrical shock, or fire.

• Absolutely provide a dedicated earth leakage circut breaker and a thermal

overload relay suitable for the pump (available on the market). Failure

to follow this warning can cause electrical shock or explosion when the

product fails or an electrical leakage occurs.

Operate well within the capacity of the power supply and wiring.

Grounding

WARNING

Be sure to install the ground wire securely. Failure to observe this precaution

could damage the pump and cause current leakage, which may lead to

electrical shock.

CAUTION

Do not connect the ground wire to a gas pipe, water pipe, lightning rod, or

telephone ground wire. Improper grounding could cause electrical shock.

Connecting the Power Plug

WARNING

Before inserting the power plug or connecting the wires to the terminal

board, make sure that the power supply (i.e. circuit breaker) is properly

disconnected. Failure to do so may lead to electrical shock, short, or injury

caused by the unintended starting of the pump.

CAUTION

Do not use damaged cabtyre cables, power plugs, or loose power outlets.

Failure to observe this precaution could lead to electrical shock, short circuit,

or fire.

Follow the diagram on the right to connect the power.

When a single-phase power source is used, con-

nect the leads to the control panel terminals as

shown in the diagram, making sure they do not

become twisted together.

When a three-phase power source is used, con-

nect the leads to the control panel terminals as

shown in the diagram, making sure they do not

become twisted together.

Single Phase

Three Phase

U-Red(Brown)

G-Green

(Green/Yellow)

W-Black(Black)

V-White(Grey)

U V W

G

L1-Red(Brown)

G-Green

(Green/Yellow)

L2-White(Blue)

L1 L2 G

When using a three-prong grounded plug,connect as shown in the drawing.

CAUTION

Be sure to use a dedicated

power supply with a ground

leakage circuit breaker.

Note:

the shape of the plug may differ from that

shown in the illustration.

(This drawing shows a 2-pin plug type.)

5 ELECTRICAL WIRING

CAUTION

Beware that the power plug

varies by country or region.

Note:

The cabtyre cable, if it is unused, is termi-

nally processed. If there is a need to peel

off the cable again, have the terminal pro-

cessed.