Precautions during test operation and operation – Tsurumi PU Submersible Vortex Sewage Pump User Manual

Page 3

Advertising
background image

-2-

CAUTION

●Do not scratch, fold, twist, make

alterations, or bundle the cable, or

use it as a lifting device. The cable

may be damaged, which may

cause electrical leakage, short-

circuit, electrical shock, or fire.

●Be sure to provide a ground wire

securely. Do not connect the

ground wire to a gas pipe, water

pipe, lightening rod, or telephone

ground wire. Improper grounding

could cause electrical shock.

●Do not use the cabtyre cable, power

plug, or power outlet if it is damaged

or it is not closely fitted. Connect

every conductor of the cabtyre cable

securely to the terminals. Failure to

observe this can lead to electrical

shock, short-circuit, or fire.

●Install the discharge pipe securely

so that no water leakage may

occur. In addition, It is suggested to

provide a stand-by pump in case of

flooding. Failure to do so may

result in damage to nearby walls,

floors, and other equipment.

●When the product will be carried by

hand, decide the number of persons

considering the mass of the product.

When lifting up the product, do

not attempt to do it by simply

bowing from the waist. Use the

knees, too, to protect your waist.

●This pump is neither dust-proof nor

explosion-proof. Do not use it at a

dusty place or at a place where

toxic, corrosive or explosive gas is

present. Use in such places

could cause fire or explosion.

●If a hose is used for the discharge

line, take a measure to prevent the

hose from shaking. If the hose

shakes, you may be wet or

injured.

●Prevent a metallic object or dust

from sticking to the power plug.

Adhesion of foreign object to the

plug could cause electrical

shock, short-circuit, or fire.

PRECAUTIONS DURING TEST OPERATION AND OPERATION

CAUTION

WARNING

●Never try to operate the pump if

somebody is present in the pump

sump. If an electrical leakage

occurs, it can cause electrical

shock.

●When changing power connection is

needed to correct the direction of

rotation, be sure to turn off the

power supply (earth leakage circuit

breaker, etc.), and perform the work

after making sure that the impeller

has stopped completely. Failure to

do so may lead to electrical

shock, short-circuit, or injury.

●Never start the pump while it is

suspended, as the unit may jerk

and could lead to injury.

●When inspecting the pump, be sure

to turn off the power supply (earth

leakage circuit breaker, etc.) so that

the pump may not start acciden-

tally. Failure to do so may lead to

a serious accident.

●Do not operate the product under

any voltage other than described

on the nameplate with the voltage

variation limit within ±10%. If it is

operated with a generator, it is

strongly suggested not to operate

other equipment with the same

generator. Failure to observe

this caution may cause

malfunction and breakdown of

the product, which may lead to

electrical leakage or electrical

shock.

●Do not touch the product with bare

hands during or immediate after

the operation, as the product may

become very hot during operation.

Failure to observe this caution

may lead to be burned.

●Do not use the product in a liquid

other than water. Use in oil, salt

water or organic solvents will

damage it, which may lead to

electrical leakage or electrical

shock.

●Do not run the product dry or

operate it with its valve (sluice or

gate valve) closed, as doing so

will damage the product, which

may lead to electrical leakage or

electrical shock.

For water

only

Rated

Voltage

STOP

OFF

OFF