3.2.10 SNMP Settings

a.

Select “d” from “Input choice and enter (1~8,a~f):” to change SNMP Name field.

Note that if you press enter, MB5001C will fill in a default name equal to its MAC.

b. Select

e” from “Input choice and enter (1~8,a~f):” to change SNMP Location field.

c.

Select “f” from “Input choice and enter (1~8,a~f):” to change SNMP Contact field.

3.3 Configuration Using Web Browser

1. Make sure one PC is located on the same network sub-net as MB5001C
2. Open a web browser, then type in the IP address of MB5001C to be configured. Default user name

is admin and default password is null (leave it blank).

3. MB5001C

‟s network, link mode and COM ports settings can be configured in different web pages.

4. C

lick “Save Configuration” to save settings.

5.

Click ”Restart” button to make the change effective if necessary.

It is also possible to modify various settings through the web server interface. To do so, please follow the
steps below.

3.3.1 Log in to the System

1. From web browser, type in the IP address of MB5001C in the URL.

Example: http://10.0.50.100

2. The following authentication screen appears. (Figure 3.16) Please type in user name and password

then click on OK. The user name is admin and password is left it blank by default.

Figure 3.16 login the system via Web

3. The following overview page appears.( Figure 3.17)