Mk-5000g troubleshooting – Barranca Diamond MK-5009G/5013G User Manual

Page 34

Advertising
background image

34

(F)

Locate Cooling Channels inside

Blade Guard

Cooling Flow Stopped

(A)

Check Cooling Flow

Control Valve is open

(B)

Remove Transfer Tube from

Blade Guard

(C)

Place Water Pump in clean

water source and check for flow

(if no flow go to step G)

“Rodding” cooling channels is performed by removing the flow control valve and then inserting a small wire rod

through the cooling channel inlet, located on the underside of the Blade Guard. The cooling channels should be

“rodded” until each of the outlet ports are open and free of foreign debris.

NOTE:

(D)

Verify Cooling Valve operation

by removing the valve from the

Blade Guard

(E)

Attach the Cooling Valve to the

Transfer Tube to verify flow –

if no flow, replace valve

(G)

Rod Cooling Channels and

recheck flow

(H)

Verify Water Pump suction is

clean and pump impeller is

turning. Pump Impeller is inside

water inlet

(I)

Verify Water Pump drive end is

in the operating position

MK-5000G TROUBLESHOOTING