Condux Fiber Optic Cable Puller Trailer User Manual

Page 15

Advertising
background image

15

4.

Zero the display. Press the “Prog” button.

5.

Alarms: When Tension Limiter switch is in the “OFF” position the audio alarm
will sound and the light will come on when the tension limit is reached. When
the Tension Limiter switch is in the “ON” position the puller will also stop pulling
when the tension limit is reached (figure 5)

!CAUTION: Damage to cable may result from excessive pulling forces. Use
precautions to safeguard against overload conditions.

D. DIGITAL CHART RECORDER SET UP
The Digital Chart Recorder is the next generation Solid State Data Recorder/Panel
Recorder. This instrument has all the capability of a traditional paper recorder –
variable chart speeds, the ability to review historic data, see trends and more. All
pull data is stored on the 256MB Compact Flash Card that comes with the unit.

1. Name File Press “MENU” button to enter the Menu screen. Use

▲ and ▼

arrows to scroll to RECORD MODE and press menu. Next, scroll to “NAME
FILE” and press MENU. Use the

▲ and ▼ buttons to scroll through letters and

the

◄ and ► buttons to move spaces. (figures 16e-h). Once the name is set

press “MENU” button to go back to Record Mode. From Record Mode,

◄ or ►

will return to Menu screen. Pressing

◄ or ►again will return to charting screen.

Figure 16e

Figure 16g

Figure 16f

Figure 16h

Advertising