C shared optional backup supply – ElmoMC Gold Line Digital Servo Drives-Gold Whistle User Manual

Page 40

Advertising
background image

Gold Whistle Installation Guide

Installation

MAN-G-WHIIG (Ver. 1.208)

www.elmomc.com

40

4.7.2.4.c

Shared Optional Backup Supply

A Main DC Power Supply can be designed to supply power to the drive’s logic as well as to the
Main Power (see Figure 8 and the upper portion of Figure 10). If backup functionality is
required for continuous operation of the drive’s logic in the event of a main power-out, a
backup supply can be connected by implementing “diode coupling”, see the Aux. Backup
Supply in Figure 10.

Figure 10: Separate Auxiliary Supply Connection Diagram