5.2. Environmental Conditions

Feature

Details

Ambient operating temperature

0 °C to 40 °C (32 °F to 104 °F)

Storage temperature

-20 °C to +85 °C ( -4 °F to +185 °F)

Maximum non-condensing humidity

90%

Maximum Operating Altitude

2,000 m (6562 feet)

Protection level

IP64

5.3. Control Specifications

5.3.1.

Current Loop

Feature

Details

Controller type

Vector, digital

Compensation for bus voltage
variations

“On-the-fly” automatic gain scheduling

Motor types

AC brushless (sinusoidal)

DC brushless (trapezoidal)

DC brush

Linear motors

“Voice” coils

Current control

Fully digital

Sinusoidal with vector control

Programmable PI control filter based on a

pair of PI controls of AC current signals and

constant power at high speed

Current loop bandwidth

> 4 kHz closed loop

Current sampling time

Programmable 40 to 120 µsec

Current sampling rate

Up to 25 kHz; default 20 kHz