74

5.4. Feedbacks

5.4.1.

Feedback Supply Voltage

The Gold Whistle has two feedback ports (Main and Auxiliary). The Gold Whistle supplies
voltage only to the main feedback device and to the auxiliary feedback device if needed

Feature

Details

Encoder supply voltage

5 V ± 5% @ 2 x 200 mA (maximum)

5.4.2.

Feedback Options

The Gold Whistle can receive and process feedback input from diverse types of devices.

5.4.2.1.

Incremental Encoder Input

Feature

Details

Encoder format

A, B and Index

Differential

Quadrature

Interface

RS-422

Input resistance

Differential: 120 Ω

Maximum incremental encoder frequency

Maximum absolute: 75 Megacounts per
second (18 MHz PPS (Pulses Per Second))

Minimum quadrature input period (PIN)

53 nsec

Minimum quadrature input high/low period
(PHL)

26 nsec

Minimum quadrature phase period (PPH)

13 nsec

Maximum encoder input voltage range

Common mode: ± 7 V
Differential mode: ± 7 V

Figure 35: Main Feedback - Encoder Phase Diagram