4.14.2. Heat Dissipation Data

Heat Dissipation is shown in graphically below:

Whistle - 60 Series Power Dissipation

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

0

0.75 1.5 2.25 3

3.75 4.5 5.25 6

6.75 7.5 8.25 9

9.75

Peak Current (A)

Po

w

er

D

issi

pat

io

n (

W

at

ts

50V
40V
30V
20V

Standard 40 °C Ambient Temp.

External

Heatsink

Required

Heatsink

not

Required

Gold

Whistle 100 Series Power Dissipation

0.0

1.0

2.0

3.0

4.0

5.0

6.0

0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5

Peak Current (A)

Pow

er

D

is

si

pa

tion (

W

)

85VDC
70VDC
50VDC

Standard 40 °C Ambient Temp.

External

Heatsink

Required

Heatsink

not

Required

Gold