Safe torque off (sto), Sto input interfaces – ttl mode – ElmoMC Gold Line Digital Servo Drives-Gold Whistle User Manual

Page 81

Advertising
background image

Gold Whistle Installation Guide

Technical Specifications

MAN-G-WHIIG (Ver. 1.208)

www.elmomc.com

81

5.6. Safe Torque Off (STO)

The Gold Whistle has two STO (Safe Torque Off) inputs.

5.6.1.

STO Input Interfaces – TTL Mode

Feature

Details

Type of input

Optically isolated

Input current for all inputs

Iin = 3.8 mA @ Vin = 5 V

High-level input voltage

2.4 V < Vin < 15 V, 5 V typical

Low-level input voltage

0 V < Vin < 0.8 V

Minimum pulse width

>3 ms

Figure 38: STO Input Schematic

Advertising