Hornet and Bee Installation Guide
Installation
MAN-HRBEIG (Ver. 1.304)
29
3.8.3.
Shared Supply
A "Main" DC Power Supply can be designed to supply power to the drive's Logic as well as to
the Main Power (see Figure 8). If backup functionality is required (for storing control
parameters in case of power-outs) an additional backup supply can be connected by
implementing 'diode coupling' (see the Auxiliary Backup Supply in Figure 10).
Figure 10: Shared Supply Connection Diagram