4

Operation

75

OverTemp

You can change how an over-temperature situation is indicated in order to control stray

light.

Visible (Vivid, Lustr+, Fire and Ice, Studio HD)

The fixture produces a low-level, red light from the LED array, displays a warning message

on the LCD, turns on the LCD backlight, and turns on the error indicator light.

Visible (Studio Daylight and Studio Tungsten)

The fixture produces a low-level light from only some of the LEDs in the LED array, displays

a warning message on the LCD, turns on the LCD backlight, and turns on the error indicator

light.

Dark

The fixture turns off the LED array entirely and displays a warning message on the LCD

without turning on the LCD backlight.

Step 1:

With OverTemp selected, press [

].

Figure-4.43 Setting Over Temperature Indication.

Step 2:

Continue to press [

] to toggle between the two options.

Step 3:

Press [

] or [

]to commit the option.

For more information, see

Thermal Shutdown Warning, page 47

.

Restore Defaults

You can restore the fixture to the factory settings. This function clears all custom settings

including all changes to Presets and Sequences.

Step 1:

With Restore Defaults selected, press [

].

Step 2:

When asked if you are sure, select Yes and press [

].

Step 3:

Press [

].

N o t e :

When returning to normal operation, after the fixture has been in a shut-down

status, the LED array automatically transitions its output back to the current control

signal or stand-alone operation over a 10-second crossfade. There is no required

reset function once the fixture temperature returns to a safe level.

Local Settings

Backlight: 100%
BLght time out:

1 min

Language: English
Status Indicators:

Off

OverTemp

: Visible

Restore Defaults