Operating Instructions AR Evaluation Unit CES-AR-AES-12

13

Connecting monitoring outputs on the AR evaluation

unit

The AR evaluation unit has 14 short-circuit-proof semiconductor outputs that can 

be used to signal different operating states, e.g. to a PLC. If the monitoring output 

is active, a voltage of max. 24 V DC is present at the related terminal (referred to 

the potential at terminal 0 V).

O3

O12 OUT

AR

DIA

O2

O1

min. 0,8x U

B

; max. 20 mA

Fig. 8: Monitoring outputs CES-AR-AES

Significance of the signals with monitoring output active:

 Ì

O1 ... O12:   Status of safety switches 1 ... 12 

(actuator at operating distance or guard locking status)

 Ì

OUT AR: 

 All connected safety switches in state Enable.

(All actuators in operating distance and all guard locking devices 

active)

 Ì

DIA:  

 Fault on the AR evaluation unit or on a safety switch in the AR 

switch chain, or feedback loop was open during start (see section 

Troubleshooting)

Assignment of safety switches to monitoring outputs

At least one monitoring output is assigned to each safety switch in the AR switch 

chain. The safety switch with bridging plug has the monitoring output O1. From 

here, the output assignments are incremented up to the last switch in the chain.
Several monitoring outputs are occupied depending on the switch type, e.g. one 

monitoring output for the door position and one for the guard locking status.
The table below shows how many monitoring outputs the individual safety switches 

occupy.

Series

Number (type) of monitoring outputs

CES-AR

1

(door position, OUT or diagnostics DIA)

CET1/2-AR

1

(status of guard locking OUT)

CET3/4-AR

2

(door position OUT D and status of guard locking OUT)