Operating Instructions AR Evaluation Unit CES-AR-AES-12

18

Technical data

Parameter

Value

Unit

min.

typ.

max.

Housing material

Plastic PA6.6

Dimensions

114 x 99 x 22.5

mm

Weight

0.25

kg

Ambient temperature at U

B

 = DC 24 V

-20

-

+55

°C

Atmospheric humidity, not condensing

-

-

80

%

Degree of protection according to EN 60529

IP20

Degree of contamination

2

Mounting

DIN rail 35 mm according to EN 60715

Connection (plug-in screw terminals/coded)

0.14

-

2.5

mm²

Operating voltage U

B

 (regulated, residual ripple < 5 %)

24 ± 10%

V DC

Current consumption I

B

 (with relay energized) 

1)

-

1.2 

1)

-

A

External fuse (operating voltage U

B

)

-

2.5

8

A gG

Safety contacts

4 (relays with internally monitored contacts)

Switching current (relay outputs) 

mA

- at switching voltage  AC/DC  21 ... 60 V

1

-

300

- at switching voltage  AC/DC  5 ... 30 V

10

-

6000

- at switching voltage  AC   

5 ... 230 V

10

-

5000

External fuse (safety circuit) according to EN 60269-1

6 A gG or 6 A circuit breaker (characteristic B or C)

Utilization category acc. to EN 60947-5-1

AC-12 60V 0.3A   / DC-12 60V 0.3A

AC-12 30V 6A / DC-12 30V 6A

AC-15 230V 5A / DC-13 24V 5A

Rated insulation voltage U

i

250

V

Rated impulse withstand voltage U

imp

4

kV

Resilience to vibration

In acc. with EN 60947-5-2

Mechanical operating cycles (relays)

10 x 10

6

Current via feedback loop Y1/Y2

5

8

10

mA

Permissible resistance via feedback loop

-

-

600

W

Monitoring outputs (O1 ... O12, DIA and OUT AR,  

semiconductor outputs, p-switching, short-circuit-proof)
- Output voltage

0.8 x U

B

-

U

B

V DC

- Max. load

-

-

20

mA

- Switching frequency

-

1

-

Hz

Start button input S, test input TST
- Input voltage  

LOW

0

-

2

V DC

HIGH

15

-

U

B

- Input current  

HIGH

5

8

10

mA

Safety inputs IA, IB

2 (for CES-AR switch chain)

Number of connectible safety switches

Max. 12

EMC protection requirements 

In acc. with EN 60947-5-3

Reliability values according to EN ISO 13849-1
as a function of the switching current at 24 V DC

0.1 A

1 A

3 A

Category

4

Performance Level (PL)

e

PFH

d

1.5 x 10

-8

Mission time

20

years

Number of switching cycles/year

720 000

540 000

107 000