Operating Instructions AR Evaluation Unit CES-AR-AES-12

6

Function

The AR evaluation unit is used to evaluate the individual safety switches in an AR 

switch chain and to reliably interrupt a safety circuit. 
The unit has two inputs for the connection of an AR switch chain. The safety contacts 

are switched as a function of the input signals. Downstream parts of the safety 

circuit can be monitored using a feedback loop.
The switching states of the connected safety switches can be signaled by means 

of monitoring outputs.
If the actuator on one of the safety switches in the AR switch chain is moved out 

of the operating distance or if guard locking is deactivated, the AR evaluation unit 

opens its relay contacts and the corresponding monitoring output is switched off.
The system is designed so that failures will not result in the loss of the safety func-

tion. The occurrence of failures is detected by cyclic self-monitoring at the latest 

at the next demand to close the safety contacts.
The system can be started either manually using a start button or automatically. 

Block diagram CES-AR-AES-12

Fig. 1: Block diagram AR evaluation unit

Mounting

Caution!

Safety  switches  must  not  be  bypassed  (bridging  of  contacts),  turned  away, 
removed or otherwise rendered ineffective.

 Ì

On this topic pay attention in particular to the measures for reducing the pos-
sibility of bypassing according to EN 1088:1995.A2:2008, sec. 5.7.

 Ì

The AR evaluation unit must be mounted in a control cabinet with a minimum 
degree of protection of IP 54. A snap-in element on the rear of the device is 
used for fastening to a DIN rail.

 Ì

If several evaluation units are mounted side by side in a control cabinet with-
out air circulation (e.g. fan), a minimum distance of 10 mm must be main-
tained between the evaluation units. 
This distance enables the heat from the evaluation unit to dissipate.

Important!

Follow the mounting instructions in the accompanying documents for the safety 
switches connected.

UB
X5:4

0V

X6:3

switch chain

Monitoring Outputs

Feedback

Loop

13

23

14

24

33

43

34

44

098225

DC 24 V

O1

X3:1

O2

X3:2

0V AR

X8:4

UB AR

X8:3

S

X5:3

DIA

X6:2

IB

X8:2

Y1

X5:1

Y2

X5:2

IA

X8:1

O3

X3:3

O4

X3:4

O5

X7:1

O6

X7:2

O7

X7:3

O8

X7:4

O9

X4:1

O10

X4:2

O11

X4:3

O12

X4:4

OUT AR

X6:1

UB
X6:4

CES- AR

Advertising