Johnson Systems EDI-120 Control Retrofit User Manual

Page 12

Advertising
background image

www.johnsonsystems.com

12

+12V

Common

+12V

Analog

Input

1 Thru 4

Common

+12V

Analog

Input

1 Thru 4

Maintained

Normally

Open

Switch

Contact

Normally

Open

Thermostat

Switch

Overtemp

Input

Normally

Open

Common

Maintained

Normally

Open

Switch

Contact

Common

Fire

Alarm

Input

Maintained

Normally

Open

Switch

Contact

Common

Security

Alarm

Input

Maintained

Normally

Open

Switch

Contact

Common

Auxiliary

Input

+12V

100mA

Max

Open

Collector

Output

+12VDC Power Supply Output
• A regulated +12VDC power supply is available for powering external

devices.

• Terminate on +12VDC and COMMON on the 6-position breakaway

connector provided.

• External devices should not exceed the maximum combined current draw

of 2 Amps.

0-10VDC Analog Inputs or Load Shed Contact Inputs

• Four (4) analog inputs terminate on the 6-position breakaway connector

provided.

• Inputs can be configured for normal or load shed mode of operation.

• Inputs can be patched to any combination of dimmer control outputs.

• Programmed in the “ANA MODE” and “ANA PAT” menus.

See page 24 and 25 for details.

Over-Temperature Input (Normally Open)

• OVERTEMP INPUT (N.O.) is terminated on the 6-position breakaway

connector provided.

• Disables all dimmer outputs when the thermostat contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common

(COMMON).

Fire Alarm Input (Normally Open)

• FIRE ALARM (N.O.) is terminated on the 6-position breakaway connector

provided.

• Triggers selected channels to turn on when contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common (COM).

• Programmed in the “F-ALARM” menu. See page 27 for details.

Security Alarm Input (Normally Open)

• SECURITY ALARM (N.O.) is terminated on the 6-position breakaway

connector provided.

• Triggers selected channels to cycle on and off at a 1 Hertz rate when

contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common (COM).

• Programmed in the “S-ALARM” menu. See page 27 for details.

Auxiliary Input (Normally Open)

• AUXIALIARY INPUT (N.O.) is terminated on the 6-position breakaway

connector provided.

• Triggers 1 of 12 presets when contact/switch is closed.

• Controlled via a maintained contact/switch to low-voltage common (COM).

• Programmed in the “AUX IN” menu. See page 26 for details.

Open Collector Output

• OPEN COLLECTOR OUTPUT is terminated on the 6-position breakaway

connector provided.

• Sink up to 100mA.

• Trigger Solid State Relays (SSR) or other external devices.

• Controlled via DMX and/or Analog Input 4.

• Programmed in the “OC MODE” menu. See page 26 for details.