Johnson Systems EDI-120 Control Retrofit User Manual

Page 28

Advertising
background image

www.johnsonsystems.com

28

C 120 ØB

Press EXECUTE to toggle the patch to Phase B (ØB).

C 120 ØC

Press EXECUTE to toggle the patch to Phase C (ØC).

Press ESCAPE to exit the menu and save the desired settings.

Press RESET to exit the menu without saving.

The menu will automatically timeout after 5 minutes of inactivity and save.

32. WARMING

Turn the “lamp warming” feature on or off.

The unique “lamp warming” feature is activated by a control level above 0% and

lowers the in-rush current to the dimmer (cold lamp filament) by up to 70%. This

results in significantly increased lamp filament life and lower long-term operating costs.

WARMING is set to ON by factory default, but may be turned OFF for some

installation applications. With WARMING set to ON, a maximum delay of 245

milliseconds is introduced to “warm” the lamp when it is turned on. For fast chase

effects the delay may be undesirable, in which case, the “lamp warming” feature can

be turned off. Note that when standby mode is enabled the microcontroller goes to

sleep within 5 seconds of inactivity on the control inputs, and there is delay of 150

milliseconds for the microcontroller to wake up and restart normal run mode. To

ensure virtually instant dimmer control response, set STANDBY to DISABLED and

WARMING to OFF.

Press EXECUTE to enter the menu and configure the lamp warming mode.

DISABLED

This menu is disabled to help prevent inadvertent changes. Proceed to enable.

ENABLED

Press and hold MENU (

) and MENU (

) at the same time for 4-5 seconds.

ON

Press EXECUTE to toggle the lamp warming mode from ON to OFF.

OFF

Press EXECUTE to toggle the lamp warming mode from OFF to ON.

Press ESCAPE or RESET to exit the menu.

Any change in the configuration is automatically saved.

33. LINE V

View the RMS line voltage for each power phase.

Press EXECUTE to enter the menu and view the line voltage of each phase.

ØA=120.0

Shows the line voltage of Phase A.

ØB=120.0

Press MENU ( ) to view the line voltage of Phase B.

ØC=120.0

Press MENU ( ) to view the line voltage of Phase C.

Press ESCAPE or RESET to exit the menu.

34. LINE F

View the line frequency of phase A.

60.0 Hz

Shows the frequency.

35. CTL TEMP

View the temperature of the microcontroller.

+91°F

Shows the temperature in degrees Fahrenheit.

+33°C

Press EXECUTE to toggle units to degrees Celsius.

36. RTIME

View the total run time of the microcontroller.

The run time counter keeps track of the total time the microcontroller is powered up.

The maximum time is 99999 hours, 59 minutes, 59 seconds, or about 11.4 years.

System operation is not effected when the maximum run time is reached and can be

reset to zero at the factory.

RTIME SS

Shows the number of seconds (SS) of run time.

HHHHH:MM

Shows the number of hours (HHHHH) and minutes (MM) of run time.

37. HARD-KEY

View the microcontroller’s unique six-character hard-key code.

EDI-120 retrofit control systems may be shipped with an invalid hard-key code of

000000. A valid hard-key must be entered before the run time (RTIME) counter

reaches 2160 hours / 90 days. If the run time expires without a valid hard-key the

LCD display will show a runtime counter error (RTC ERR!) and all dimmer control

outputs will be disabled.

HARD-KEY

A dash (-) between hard and key represents a valid hard-key.

HARD KEY

A blank space between hard and key represents an invalid hard-key.