Johnson Systems EDI-120 Control Retrofit User Manual

Page 23

Advertising
background image

www.johnsonsystems.com

23

DIM#:001

Press EXECUTE to select the first dimmer number (DIM#) in the block.

DIM#:120

Press MENU ( ) to edit the dimmer number (DIM#) from 001 to 120.

DIM#:001

Press MENU ( ) and MENU ( ) at the same time to toggle back to 001.

DMXA:001

Press EXECUTE to select the DMX A (DMXA) start address for the block.

DMXA:512

Press MENU ( ) to edit the DMX A (DMXA) start address from 001 to 512.

DMXA:001

Press MENU ( ) and MENU ( ) at the same time to toggle back to 001.

#DIM:001

Press EXECUTE to select the number of dimmers (#DIM) in the block.

#DIM:120

Press MENU ( ) to edit the number of dimmers (#DIM) from 001 to 120.

#DIM:001

Press MENU ( ) and MENU ( ) at the same time to toggle back to 001.

PROCEED?

Press EXECUTE to proceed.

SURE ???

Press EXECUTE if you are sure.

DONE !!!

Indicates the sequential block patch has been completed.

Repeat until all required blocks of sequential dimmers have been patched.

CLEAR?

Press EXECUTE to clear the entire patch.

SURE ???

Press EXECUTE to proceed if you are sure.

DONE !!!

Indicates the entire patch has been cleared.

Press ESCAPE to exit the menu and save the selected patch.

NOTE: Be sure to BACKUP any configuration changes!

NOTE: With DMX patch mode activated, any configuration within the ADDRESS,

DMX MODE, 2 RM SET and DC PATCH menus is ignored, and the DMX

patch configured within this menu takes precedence.

13. DMXB PAT

Patch the 120 dimmer (PWM) outputs to any DMX B input channel.

Refer to the DMXA PAT menu for further information.

The DMXA PAT menu is used to patch dimmers to DMX A input channels, while the

DMXB PAT menu is used to patch dimmers to DMX B input channels.

14. SH TIME

Set the DMX status hold time from 0 to 99 minutes or infinite.

When DMX is disconnected the system will hold the status of the last received DMX

levels for the selected amount of time. When activated, the LCD display shows a

countdown of the status hold time or infinite hold.

Press EXECUTE to enter the menu.

HTIME 00

Displays the current DMX status hold time (HTIME) setting.

HTIME 99

Press MENU ( ) to set the desired hold time from 00 to 99 minutes.

HTIME XX

Press MENU ( ) to set the desired hold time to infinite (XX).

HTIME 00

Press MENU ( ) and MENU ( ) at the same time to toggle back to 00.

Press ESCAPE to exit the menu and save the desired DMX status hold time.

Press RESET to exit the menu without saving.

The menu will automatically timeout after 5 minutes of inactivity and save.

15. DC PATCH

Configure the dimmer to channel patch for the dimmer rack.

Each of the 120 dimmer (PWM) outputs can be assigned and patched to any of the

120 control channels. Multiple dimmer outputs may be patched to a single control

channel. The dimmer to channel patch is used by other menu features to provide

transparent control of the dimmer output circuits. EDI-120 systems are typically

patched for 1 to 1 operation but may be altered for custom applications.

D001C001

Displays the dimmer (D) output (001) and its current control channel (C) patch (001).

D120C120

Press MENU ( ) to select the desired dimmer output from 001 to 120.

D120C120

Press EXECUTE to toggle between dimmer (D) and channel (C) selection.

D120C120

The cursor (_) position indicates dimmer (D) or channel (C) selection.

D120C001

Press MENU ( ) to select the desired control channel from 001 to 120.

D120C001

Press EXECUTE to toggle the cursor (_) and select another dimmer output to patch.

Press ESCAPE to exit the menu and save the desired dimmer channel patch.

Press RESET to exit the menu without saving.

The menu will automatically timeout after 5 minutes of inactivity and save.

NOTE: DMX O/P must be set to OFFSET mode for this menu to function.

T

M

Advertising