5

Diagnostics

5.3

Event of an error: Controller c300/p300 does not start

40

Lenze · Backup & Restore · Software Manual · DMS 1.3 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.3

Event of an error: Controller c300/p300 does not start

If Controller c300 or p300 does not start, the Lenze standard settings can be activated with the Reset

button.

How to activate the Lenze standard settings:

1. Switch off voltage supply.
2. Activate Reset button.
3. When the Reset button is activated, switch on voltage supply and keep the Reset button

pressed for at least 10 s.

• If the Error LED (green/red) is blinking after this action, manual mains switching is

required.

• The controller must be disconnected from the mains supply until all LEDs have gone off.