6 R

UNNING OR

P

ROGRAMMING

?

Default DS-3000 operation is in run mode, with all active input sensors summed, and the sum displayed
onscreen in the selected units. Any setting changes made in the internal programming menu are retained
after power off, so your current settings may differ from the default values. You may reset the current DS-
3000 settings to the factory default using the menu entry FACTor under the options programming page,
documented later in this document.

6.1 Entering programming mode (from run mode)

1. Press

menu

2. Display

will

show

enter pass

3. Display will show a numeric entry field 000000

4. Press

enter

to directly return to run mode, or

5. Press

up

or down to select the desired password value (default is 000001)

6. Press and hold enter

until the first programming page dsplay appears

7. Now

pressing

menu

will step through the available programming mode pages.

6.2 Entering run mode (from programming mode)

1. Press

shift

until run is displayed

2. Press and hold enter

3. Display will return to run mode and display the load using the current display settings.

6.3 Modifying a Programmed Value

1. In programming mode, Press menu until the desired programming page is displayed

2. Press

up

or down to select the sub-menu entry

3. Press

enter

to edit the currently displayed sub-menu field

a. If the field is a logical field, up or down will toggle through the available values

b. If the field is a numeric data entry field, up or down will increment or decrement the

currently highlighted digit. Press menu to step through all numeric digits, setting each
one in turn until the desired value is displayed.

c. If an enable field is selected the decimal point lights will turn on (enable) or turn off

(disable) the currently selected ports. .

4. Press

enter

to retain the newly changed value.