How-to, Uick, Rogramming – Loadstar Sensors DS-3000 Digital Load Cell Display & Controller User Manual

Page 17

Advertising
background image

DS-3000U

DS3000 User Guide

Loadstar Sensors, Inc.

Page: 17 / 48

033-01419 Rev. 4

7 Q

UICK

P

ROGRAMMING

HOW-TO

T

IPS

7.1 How to change the displayed decimal point location

1. Press

the

down

button (bottom right) and holding it down, press enter (bottom left).

2. Now release the down button while continuing to hold down enter.

3. While continuing to hold enter press up (top right) or down (bottom right) to select your desired

decimal point location. The current decimal point location is illuminated on the display while you
continue to hold down the enter button.

4. Release

enter

when the decimal point is at the desired position. The display will retain this new

decimal point selection until changed again, or reset to the factory default.

7.2 How to reset or TARE the current displayed value to zero?

1. Press and hold the enter button until the display shows tare and all the decimal points (for all

the currently active sensors) illuminate. Releasing the button will now tare all the connected and
active sensors.

7.3 How to display the load from only sensors I choose?

1. Press and hold menu until “Enter Pass” and “000000” appear on the display

2. Press

the

up

or down keys to select the programming mode password (default is 000001)

3. Press

enter

4. You are now in programming mode at the dsplay prompt. Notice the decimal points are flashing

for inactive ports, and solid on for active ports.

5. Press down, one time to the disp 1 menu. Press enter to enable or disable this port from

being displayed. It is displayed if the decimal point corresponding to the port is illuminated, it is
NOT displayed if the port is extinguished.

6. Press down as above for disp 2, disp 3, disp 4 leaving only the ports you want illuminated,

or enabled.

7. Press up to dsplay, and confirm that the decimal point is not illuminated on the ports you’ve

disabled.

8. Press

mode

until the run entry

9. Then

press

enter

to return to run mode. Your display will now only show the sum of the ports

you’ve chosen.

7.4 How do I tare only one connected sensor?

1. Press and hold menu until “Enter Pass” and “000000” appear on the display

2. Press

the

up

or down keys to select the programming mode password (default is 000001)

3. Press

enter

4. You are now in programming mode at the dsplay prompt. Press mode until you reach the tare

menu .page

5. Press

down

, to the menu entry corresponding to the sensor you want to tare- from sensor 1 ->

tare 1 to sensor 4 -> tare 4.

Advertising