background image

DS-3000U

DS3000 User Guide

Loadstar Sensors, Inc.

Page: 42 / 48

033-01419 Rev. 4

11.4 CT0 ©

Function:

TARE all currently connected sensors simultaneously

Summary:

This remote command tares all connected sensors at the same time.

11.5 ETT © (Future Command, not yet implemented)

Function:

Set function of external input

Keystrokes:

These commands remotely control the options mode page trgr entry.

ETT D

©

ETT T

©

ETT R

©

ETT B

©

Remote equivalent to Trgr

Remote equivalent to trgr t.

Remote equivalent to trgr r

Remote equivalent to trgr b

Summary:

Configure the function of external input.

11.6 TTS, TTH ©

Function:

Set tare type

Keystrokes:

These commands tell the DS-3000 how to handle default tare requests.

TTS

©

TTH

©

Soft tare attached sensors, equivalent to programming mode

page tare, field type s.

Hard tare attached sensors, equivalent to programming

mode page tare, field type h

Summary:

Tell the DS-3000 how to handle user tare requests (both front panel and
remote).

11.7 SST ©

Function:

Read Sensors internal status code

Keystrokes:

This is a debug command.

SST

©

Returns internal status code.

Summary:

Returns internal status code. This is a read only value.

11.8 LED© (Future Command, Not yet Implemented)

Function:

Sets intensity of display LED

Keystrokes:

This command sets the brightness of the display LED. The range is from 10 to

Advertising