MTS SWIFT 40 Sensor User Manual

Page 27

Advertising
background image

Specifications

SWIFT 40 Sensors

Hardware Overview

27

Transducer Interface

P

ARAMETER

S

PECIFICATION

Physical

Height

Width

Depth

Weight

Rack Mounting Kit

31.75 mm (1.25 in)

431.8 mm (17 in)

215.9 mm (8.5 in.)

*

1.68 kg (3 lb 11.1 oz)

Optional

*

Add 25.4 mm (1.0 in) for ground lugs.

Environmental

Ambient temperature

Relative humidity

0° C (32° F) to 50° C (122° F)

0 to 85%, non-condensing

Power Requirements

Input voltage

Supply current

Fuse

10–17 V DC

2 A typical, 3 A maximum at 12 V DC

3 A fast-blow

Angular velocity

Encoder limit

Processing limit

Encoder resolution

2,200 rpm maximum

10,000 rpm maximum

2048 counts per revolution
(512 pulses with quadrature)

Time delay (encoder tick to main output stable)

12 µs (typical)

Transducer cable length

100 ft maximum

Shunt cable length

100 ft maximum

Analog outputs

Voltage

Capacitive load

Current

Noise at output, with typical gains

±10 V range

(force and moment outputs)

0–5 V sawtooth (angle output)

0.01 µF maximum

6 mA maximum

7 mVpp, DC - 500 Hz (typical)
15 mVpp, DC - 500 Hz (maximum)

† Standard from MTS. Other full scale voltages can be evaluated and may be provided at special

request.

Bandwidth (bridge input to main output)

–3 dB at 30.1 kHz (typical)
90 degree at 16.6 kHz (typical)