Informations / information / informationen – Sulky VISION 2 WPB User Manual

Page 55

Advertising
background image

55

Informations / Information / Informationen

1

4

GB

Faults - Solutions

E

F

AULTS

S

OLUTIONS

The unit does not lit up

Check

- unit/power supply connections
- fuses supply line

Flow rate test

Check

- calibration factor

Repeat the test in Static mode

Shutters open to maximum then to minimum

Check

- Tractor drive rate coefficient.
- spreading width
(24.00, beware of the decimal sign)

The unit lits up but the rams do not move

Check

- fuses
- the battery power supply

Area counter reading incorrect

Check

- connection / machine
- working width
- drive rate

Flow rate

Check

- programmed flow rate
- fertiliser coefficient
- PDF rate = 540 RPM
- spreading width
- tractor drive rate

-

shutter opening/closing performance

- ram travel
- tramlining

The drive rate is incorrect

Check

- connection on unit
- sensor magnet clearance
- magnet rotation
- sensor wire continuity (100

Ω ± 10)

- 100-m coefficient

The tonnage counter reading is incorrect

Check

- connection / machine
- working width
- drive rate
- fertiliser coefficient
- shutter opening/closing

Advertising