Talos Security DR800 Series DVR User Manual User Manual

Page 43

Advertising
background image

H.264 Network DVR

- 43 -

6.4 PTZ Setup

"Main Menu" - "System" - "PTZ Setup" (Figure 6-5)

Figure 6-5

"Channel" Choose the channel to connect a speed dome camera, "ALL" means all channels.
"DEV Address" Set the address(es) of speed dome camera(s). The numerical ranges 0-255.
Note: The address must be consistent with the speed dome cameras, or the DVR can't control the cameras.
"Protocol" Choose the corresponding control protocol: Pelco_P, Pelco_D, the default is Pelco_D.
"Baud Rate" Choose baud rate of the corresponding speed dome camera, the range is 1200-115200, the default is 9600.
"Data Bit" The range is 5 to 8, the default is 8. "Stop Bit" Select 1 or 2, the default is 1.
"Check" The range is none, odd parity, even parity; default is none.
"Flow Control" The range is None, Xon/Xoff, the hardware, the default is None.
"Copy Setting To The Following Channel" Copy the setup to all channels.
Note: Select save after setting each channel PTZ parameter.