3-4 About the NeXUS Network

Publication 1756-UM524B-EN-P - December 2008

Supported ADP Message Types

The 1756-CLX/C module supports the following communication features referenced in
the ADP specification:

Configuration Requirements

Before you can use your 1756-CLX/C module, you must configure its IP address,
gateway, and subnet mask by specifying parameters NX00 through NX02 on the
Logix5000 controller. Refer to Appendices D and E of this manual for definitions of these
parameters.

IP Address

The IP address identifies each node on the TCP/IP network (or system of connected
networks). Each TCP/IP node on a network must have a unique IP address.
The IP address is 32 bits long and is composed of a net ID, host ID, and/or a multicast ID.
Each network can be a Class A, B, C, or D format. The class of the network determines
how an IP address is formatted.

Communication

Feature

Class

Clause (in ADP

specification)

Requirements for Conformance

Transmission

Reception

Multicast

communication

Base-1

4.1

Supported

Supported

Alive signal

Base-1

4.2

Supported

Not supported

Communication

Feature

Clause (in ADP

specification)

Requirements for Conformance

Multicast

Alive signal

Transmission

Reception

Transmission

Reception

Test support

4.5

Supported

Supported

Supported

Not supported

Maximum

message length

-

(MTU-92) bytes

(MTU-92) bytes