Install the Removable Terminal Block

Read this for information if a removable terminal block (RTB) is supplied
with your wiring base assembly, noting that 1734-TOP and 1734-TOPS bases
do not have an RTB.
To insert the RTB, proceed as follows. Note that if you pull up on the RTB
handle to remove the RTB, you can remove and replace the mounting base as
necessary without removing any of the wiring.

1. Insert the end opposite the handle into the base unit, noting that this

end has a curved section that engages with the wiring base.

2. Rotate the terminal block into the wiring base until it locks itself into

place.

3. If an I/O module is installed, snap the RTB handle into place on the

module.

Remove a Mounting Base

To remove a mounting base, you must first remove any installed module and
the module installed in the base to the right.

1. For a module with a two-piece terminal base, use these steps;

otherwise, use

step 2

.

a. Remove the removable terminal block (RTB), if wired.

b. Unlatch the RTB handle on the I/O module.

c. Pull on the RTB handle to remove the RTB.

2. Press on the module lock on the top of the module.

3. Pull on the I/O module to remove from the base.

4. Repeat steps 1, 2, 3, and 4 for the module to the right.

5. Lift straight up to remove.