Initial powerup of the dl5 – Rockwell Automation 2706-DXX Dataliner Message Display DL5 Series User Manual
Page 18
2706-UM001A-US-P
2-4
Getting Started
Initial Power Up of the DL5
When DC power is applied to the DL5, it will display:
Wait several seconds for the next display:
The memory display indicates the device memory capacity:
•
2Kbyte for Catalog No. 2706-D11J2 and -D21J2
•
8Kbyte for Catalog No. 2706-D21J8.
The SELF TEST OK display indicates that all of the diagnostic tests have
been completed.
After the diagnostic tests are completed the DL5 will display:
Indicating the current baud rate of the RS-232 port. (Default is 9600 baud).
Then it will display the serial port address:.
And then depending on the DIP switch setting:
'/
/
7(67,1*
9[[[
Two separate displays on 1-Line DL5
All of the light segments are turned on.
0(025< [ .
6(/) 7(67 2.
%$8' 5$7(
$''5(66
6(5,$/ 352*5$0
6(5,$/ 75,**(5