14 - specifications, Electrical, Specifications – Rockwell Automation 2706-DXX Dataliner Message Display DL5 Series User Manual

Page 97: Chapter

Advertising
background image

2706-UM001A-US-P

Chapter

14

Specifications

Electrical

Input Power Requirements

Current:

250 mA maximum steady-state @ 12 VDC input.

Power:

3 Watts maximum

Ripple:

5% of input voltage p-p maximum

Noise:

5% of input voltage p-p maximum

Voltage

12-24 VDC

Operating and Inrush Currents

12 VDC

250 mA oper. (300 mA inrush)

24 VDC

125 mA oper. (300 mA inrush)

Parallel Port

16 data input lines (14 data lines and 2 strobe lines for BCD and Binary
modes) and 1 parallel port select input.

Parallel Port Data Input Voltage

5 to 24 volts DC

Voltage Levels for Positive Logic

High:

Recognized

3.5 to 24.0 VDC

Indeterminate

0.9 to 3.5 VDC

Low:

Recognized

0.0 to 0.9 VDC

Indeterminate

0.9 to 3.5 VDC

Voltage Levels For Negative Logic

Low:

Recognized

3.5 to 24.0 VDC

Indeterminate

0.9 to 3.5 VDC

High:

Recognized

0.0 to 0.9 VDC

Indeterminate

0.9 to 3.5 VDC

Advertising