Round robin mode – Rockwell Automation 2706-DXX Dataliner Message Display DL5 Series User Manual

Page 82

Advertising
background image

2706-UM001A-US-P

10-2

Using the DL5 Parallel Port to Replace Pilot Lights

Round Robin Mode

In the Round Robin mode of operation you can specify both an OFF state
message and an ON state message for each input. Messages are scanned in
sequence beginning with data line D0 and ending with data line D15. If
several inputs are ON, the DL5 displays the messages in the sequence that
they are scanned. The following table lists the message numbers that are
assigned to each of the sixteen inputs.

Notice that each of the sixteen data lines listed in the table has both an ON
message number and an OFF message number assigned. You do not have to
program both an OFF and an ON message for each input. You can program
only an ON or only an OFF state message; or no message at all.

Data Line No.

ON Message No. OFF Message No.

D0

1

17

D1

2

18

D2

3

19

D3

4

20

D4

5

21

D5

6

22

D6

7

23

D7

8

24

D8

9

25

D9

10

26

D10

11

27

D11

12

28

D12

13

29

D13

14

30

D14

15

31

D15

16

32