Chapter

6

Using the Serial Port

Chapter Objectives

The DL5 has a full duplexed RS-232 serial port which is used for:

communication with the offline programmer and for programming input
from a “dumb” ASCII terminal.

serial triggering of messages

The operation of the serial port is determined by the Serial Trigger/
Configure DIP switch on the back of the DL5 see page 2-2. The RS-232
serial port is a 9-pin male D-shell connector located at the rear of the DL5.
A drawing of the DL5’s connector is provided below:

The RS-232 port operates at baud rates of 300, 1200 and 9600 baud. The
rate is user selectable through the Special Functions Menu or the Offline
Programmer. The default baud rate of the DL5 is 9600 baud.

Programming Cables

Cables are available to connect various programming devices. The
following table lists the cable to use with various terminals or computers:

See Appendix B for cable diagrams and descriptions.

DCD

TXD

RXD

COM

DSR

RTS

CTS

RI

DTR

1

2

4

5

3

6

7

9

8

RS-232

Serial Cable
Catalog Number

Description

2706-NC12

Personal computers with 25-pin female communication port
connector. DEC VT52, VT100, or VT101 terminals. Allen-Bradley
RAC 6000 industrial computers.

2706-NC13

Personal computers with 9-pin female communication port
connector (IBM AT and compatible). Allen-Bradley RAC 6000
industrial computers.

2706-NC14

Allen-Bradley RAC 6000 industrial computers (PC/XT).

2706-NC15

Allen-Bradley Industrial Terminals T1 through T4 (25-pin male
connector).