OPERATION

Press MENU, NEXT and ENTER. Then use the NEXT/BACK and ENTER buttons to adjust the
Security Submenu.

The various locking modes are as follows:

1. LOCK: Changes only: Parameters can be viewed, but cannot be adjusted. MUTE buttons

are valid.

2. LOCK: Changes + View: Parameters cannot be viewed or adjusted. MUTE buttons are

valid.

3. LOCK: Changes + Mutes: Parameters can be viewed, but cannot be adjusted. MUTE

buttons are not valid.

4. LOCK: Everything: Parameters cannot be viewed or adjusted. MUTE buttons are not

valid.

Once a security mode is selected, press ENTER. You will be prompted to enter a security
code. This can be from one to four characters. Any of the characters available from the
on-board selection choices may be used.

A. Press the BACK/NEXT buttons to shift the cursor to one of the four positions. Then
rotate the FREQ knob to select the desired character (letter, number or symbol).
Repeat for the other three positions.

B. Press “ENTER”, confirm the password and display as follows:

C. The system is locked when the reentered password matches the original entry
otherwise the locking operation is invalid. If invalid, the screen will show “Bad
Confirmation". If the codes match, the screen will show "Lock Success". Though up
to four characters may be used, the lock out will work with just a single character.
The initial and confirming entry must both be in the same position. NOTE: If nothing
is entered (all blanks) the unit will still lock.

7.4 Subsystem Submenu

This menu allows selection of Input Linking and a choice of "wake up time" fade in or
Mute Hold. Press MENU, NEXT and NEXT again. Then use the BACK/NEXT and ENTER but-
tons to adjust the Subsystem Submenu. Subsystem Submenu items are as follows:

1. Input option:

Determines whether the A/B and C/D inputs are linked or separate.

2. Wake up time:

Advertising