Configuring grid center, Configuring the administration console – ClearCube Grid Center Admin Guide 4.11 User Manual

Page 35

Advertising
background image

Grid Center 4.11 Administrator’s Guide

Configuring Grid Center • 29

Configuring Grid Center

Once you have logged into Grid Center for the first time, you need to configure the

Administration Console, the Blades, and the I/Ports on the network before you can

actually begin managing your network.

Configuring the Administration Console

Figure 6 on page 20 shows the Network Configuration View, which opens by default

to the User Database. To configure or edit this database, click the Configuration link

in the Main menu, then enter the settings for the following:

Table 1: Configuration Database Fields

Field Name

Description

Database Server

The system on which the database resides. The default value is localhost.

Database Type

The type of the database being used by Grid Center 4.1. The default value is MS Access.

Database Name

Required only when using a database other than MS Access.

Database Username

User name of the administrator logging into the database. Not required for MS Access.

Database Password

Password for the database. Enter a password, if desired. Not required for MS Access.

Confirm Password

Password for the database. Re-enter the password, if one is to be set.

Operating Mode

Workgroup or Domain. The authentication system works in one of two modes. In Domain

mode, group membership and user name/password combinations are authenticated against

a domain controller. In the default Workgroup mode, group membership and user name/

password combinations are authenticated against the local machine.

Security Group

Determines the group of users that should be authenticated to log in to the Grid Center

Console. If the Operating Mode is changed, the Grid Center page should be refreshed in

order to populate the correct Security Groups.

Session Timeout (Min.)

Specifies the period of time that causes Grid Center to automatically force the administrator

to log in again.

Subnet Range

Used for I/Port and Blade auto-discovery. Type the desired subnet range in the format

XXX.XXX.XXX.XXX–XXX. XXX.XXX.XXX. The addresses specified should be of Class C type.

To use a range larger than a Class C, enter multiple subnets by separating them with a +.

I/Port Refresh Time (Min.) If an I/Port does not poll the Console within this interval, it is considered idle and appears in

the GUI with a clock on the icon.

Advertising