64 • Appendix A: Using Grid Center with e100 and Capio I/Ports

Grid Center 4.11 Administrator’s Guide

Client Software

Grid Center 4.11 maintains full compatibility with the I8800 I/Port, and adds client

support for the Eon e100 XPe I/Ports, and Eon e100 and Capio One NeoLinux

I/Ports.

The Eon e100 is available with either XPe or NeoLinux. The Capio One is available

only with NeoLinux. The NeoLinux operating system and client can be installed on an

Eon e100, although this is not recommended.

Eon e100 and Capio One I/Ports from ClearCube are shipped with Grid Center Client

software pre-installed. This section provides information on how to verify that this

software is correctly installed and functions properly. It also provides information on

how to install, reinstall, or update the client software or other software snapins.

Finally, it gives information on updating or re-imaging the operating system.

I/Port System and Client Verification

The Grid Center client is programmed to start automatically on system startup on the

NeoLinux I/Ports. The XPe Eon e100 I/Port requires you to login to the I/Port before

starting the Grid Center client. (This behavior differs from the I8800 I/Port, which

auto-starts the Grid Center client and auto-connects to an allocated Blade via RDP,

and provides the user with a Windows login screen on the Blade.) On both operating

systems, a ClearCube splash screen is displayed during startup. This should be

visually verified when installing an I/Port on the desktop.

To verify whether the I/Port can connect with the Grid Center server, ping the Grid

Center Console system. On the NeoLinux I/Ports, open a

tty

session to use

ping

.

On the XPe I/Ports, run

ping

from a command window. Grid Center requires TCP

port 6500 to be open. Microsoft Remote Desktop Protocol requires TCP ports 139

and 3389 to be open.

If the I/Port can reach the Grid Center Console via

ping

but not via the Grid Center

client, you may need to reinstall the client software. Use ezRemote Manager to push

out the client, as Grid Center requires minimal client connectivity for a push to

succeed.

Note: The NeoLinux I/Ports need to be plugged into a live Ethernet connection at

startup for the network interface chip (NIC) to auto-initialize. If this does not

happen, the NIC can be started manually using the ezConnect client, or by

restarting the I/Port.

I/Port Client Configuration

The default administrator ID/ password on the XPe I/Ports is

administrator /

clearcube

. The default user ID/ password on the XPe I/Ports is

user / clearcube

.