56 • Updates

Grid Center 4.11 Administrator’s Guide

2. Click the first Browse button to locate the update file.
3. Click the second Browse button to locate the answer file.
4. Click the Update button.

Note: The Browse function checks only that a file is specified, and not a directory.

File extensions are checked when the Update button is clicked, and the

extensions for the update and answer files are verified.

Use

.zip

and

.bat

files for the I8800 and XPe Eon e100 I/Ports, and

.tar

and

.2do

files for the Capio One and Linux Eon e100 I/Ports. The Linux files are

interchangeable between the Capio One and the Linux Eon e100, but the XPe files

are not interchangeable between the I8800 and the XPe Eon e100. If you send an

I8800 file to an Eon e100, or vice versa, you will corrupt the operating system and will

need to re-image the operating system. The Eon e100 can be re-imaged in the field.

The I8800 needs to be returned to ClearCube for re-imaging.

See Appendix A: Using Grid Center with e100 and Capio I/Ports on page 61 for more