Grounding & lightning, 7 grounding & lightning – BridgeWave AR60X User Manual

Page 11

Advertising
background image

AR60X Installation Manual 

580­00517, rev B 

Figure 2­3: 14­gauge DC power cable with crimp connectors 

In addition to grounding the equipment, BridgeWave strongly recommends, and local building 
codes may require, that the power cable be protected from lightning strikes. If a copper Cat5 Ethernet 
cable is used for Network Management access, it is also necessary to install surge suppressors at each 
end of this cable. A surge suppressor must be placed within the radio enclosure (to protect the radio 
electronics) and at the building exit/entrance (to protect the indoor equipment). BridgeWave 
recommends the Dehn Patch DPA M CAT6 RJ45S 48. 

2.7  Grounding & Lightning 

Proper grounding of the outdoor equipment reduces 
electromagnetic interference, provides lightning protection, and 
protects against electrical discharge. 
Using improper techniques in lightning prone geographic areas 
may pose a danger to local personnel. 
The source and connection points for the building­to­earth ground 
in the vicinity of the antenna location should be determined.
 

It is recommended to integrate the radio ground into the building ground utilizing the pole mount 
hardware. For wall or ungrounded pole mounts connect a grounding wire to the grounding point on 
the radio. Select the size of the ground wire based on the National Electrical Code. 

In addition to grounding the equipment, BridgeWave strongly recommends, and local building 
codes may require, that the DC electrical cable be protected from lightning strikes with a surge 

Figure 2­3 (left) details a 
standard 14­gauge wire that 
has been fitted with the power 
connectors (provided) for the 
radio’s internal power supply 
necessary to mate with the 
provided power cord. A 
standard crimping/splicing 
tool (not provided) is required 
to terminate the power 
connectors onto the 14­gauge 
cable required for use with 
the unit.