BridgeWave AR60X User Manual

Page 32

Advertising
background image

AR60X Installation Manual 

580­00517, rev B 

26 

3.3 

3.0 

2.0 

1.7 

0.3 

NO 

ERRORS 

CORRECTED 

ERRORS 

UNCORRECTED 

ERRORS 

Correctable Errors Detected 

Uncorrectable Errors Detected 

Deframer Unlocked (Link Down) 

Errors 

Q

U

AL

 V

o

lt

a

g

e

 (

V

D

C

0.0 

Figure 3­10 Quality Voltage Graph

·  Quality Voltages between 3.0V and 3.3V indicate an error­free wireless link.

·  Quality Voltages between 1.5V and 3.0V indicate a low rate of errors, that the forward error 

correction will correct. The lower the voltage, the more errors are being corrected.

·  Quality Voltages between 0.5V and 1.0V indicate excessive errors in the wireless link that can 

not be corrected by the FEC. To indicate this change in error performance, the quality voltage 
will drop from 1.5V to 1.0V in a single step.

·  Quality Voltages below 0.5V indicate an unlocked deframer condition. This will be recognized 

as a link­down condition.