11. Once the fiber is connected to the radio, the radio will begin an internal link calibration. During 

this time the Link Up LED will blink for approximately 120 seconds for the AR60X. 

12. Wait until the Link Up LED is lit solid on both radios. 

13. Verify the Link Quality voltage is 3.3V (i.e., error free). Repeat steps 10­13 for the second radio. 

When a radio is power cycled, it will execute a limited version of 
the calibration process. After this time, the link should be 
functioning. This limited automatic calibration process is also 
activated if the link is down for more than 5minutes .
 

14. Remove the test cable from the radio, replace the rear plastic cover and use a wrench 

to tighten the back cover nut to the point where the back cover stops (i.e., when it hits the metal 
ring on the back metal plate). The installation is now complete. 

Auto Calibration States 

State 

Description 

Unit powered up no 
fiber connected 

Unit will be in alignment mode, there will be no automatic 
calibration event started until the fiber is connected 

Unit powered up then 
fiber cable connected 
for the first time 

The radio will perform a single calibration scan and will then go 
into normal operation mode, regardless of the results of the 
scan. (Link up or down status has no influence on the scan) 

Normal operation 
mode 

Disconnecting and reconnecting the fiber cables will not cause a 
recalibration. A recalibration will only happen if the link is 
down for more then 50 seconds. 

Forced Recalibration 

Power cycling the radio and disconnecting then reconnecting 
the fiber to the powered up radio will start the auto calibration 
routine again. If the fiber cables stay disconnected the radio will 
go back into alignment mode.