suppressor. The surge suppressor must be installed at the point where the DC electrical cable 
exits/enters the building, however, the use of a surge suppressor at the radio unit is optional since 
power cable surge suppression is built into the unit. 

If a copper Cat5 Ethernet cable is permanently installed, it is necessary to install surge suppressors at 
both ends
of this cable. A surge suppressor must be placed within the radio enclosure (to protect the 
radio electronics) and at the building exit/entrance (to protect the indoor equipment). 

For more information on recommended accessory devices and 
kits, contact BridgeWave Sales 

2.8  Environmental 

The structure to which the equipment will be mounted must be adequate to bear all wind and weather 
conditions. The wind load at high wind velocities can exceed 100 ft/lb of torque, BridgeWave highly 
recommends pole diameters of 3” or more. The environmental conditions at the location must 
conform to the operating environment specified for the equipment.