System save, System recall, Factory reset menu – Barco MatrixPRO HD/SD-SDI User Manual

Page 33: C~ензку=oéëéí=jéåì

Advertising
background image

MatrixPRO • 16x16 and 8x8 HD/SD-SDI Router • User’s Guide

23

3. Operation

Menu Structure

4. To “accept” the new IP address, press ESC at any time to exit the edit mode. The

new IP address will take effect at this point.

póëíÉã=p~îÉ

From the System Menu, select

System Save

to save all settings except routing. When

pressed, the menu briefly displays “Saving.”

póëíÉã=oЙЕ~дд

From the System Menu, select

System Recall

to recall all settings except routing.

When pressed, the menu briefly displays “Recall.”

c~Ензку=oÉëÉí=jÉåì

From the Setup Menu, select Factory Reset to display the Factory Reset Menu.

Figure 3-11. MatrixPRO Factory Reset Menu

The user must make a deliberate decision to perform a factory reset. When this function is
performed, the following conditions will take effect:

All output channels will be blanked.

The serial communications protocol will be set to RS-232 and the parameters will
be those default setting noted in the RS-232 sub-menu.

The RS-485 node number will be set to 17.

All channels will have their reclocking circuits enabled.

Vertical interval switching will be set to Enabled.

The IP address will be reset to the default value of 192.168.000.242.

FACTORY RESET

<SEL> = Yes

<ESC> = No

Advertising